4-2 Troubleshooting
Compaq ProLiant Storage System /U User Guide
Fan Array Module
Check to see if the status indicator on the fan array module is amber.
TROJ014.EPS
Fan Status Indicator
Figure 4-2. Fan status indicator
If this indicator is amber, replace the fan module as soon as possible. See
“Replacing Components” later in this chapter for important information on how
to replace this module. Failure to observe these instructions can result in
component damage.
CAUTION:
Do not allow the system to operate for more than two minutes
without a working fan module in place. Operation longer than this with no
forced air cooling, especially in systems with a full complement of drives,
may permanently damage the drives or electronics in the storage system
and result in data loss.
If you will be hot-plugging the fan array module, be sure to have everything
ready before you begin the procedure, which should normally take no more
than one minute.