D-2 Power Cord Set Requirements
Compaq ProLiant Storage System /U User Guide
Country-Specific Requirements
Use the following table to identify the appropriate accredited agency in
your country.
Table D-1
Power Cord Set Requirements - By Country
Country Accredited A
ency Applicable Note Numbers
Australia EANSW 1
Austria OVE 1
Belgium CEBC 1
Canada CSA 2
Denmark DEMKO 1
Finland SETI 1
France UTE 1
Germany VDE 1
Italy IMQ 1
Japan JIS 3
Norway NEMKO 1
Sweden SEMKO 1
Switzerland SEV 1
United Kingdom BSI 1
United States UL 2
Notes:
1. Flexible cord must be <HAR> Type HO5VV-F, 3-conductor, 1.0 mm
2
conductor size. Power
cord set fittings (appliance coupler and wall plug) must bear the certification mark of the
agency responsible for evaluation in the country where it will be used.
2. Flexible cord must be Type SVT or equivalent, No. 18 AWG, 3-conductor. Wall plug must be
a two-pole grounding type with a NEMA 5-15P (15A, 125V).
3. Appliance coupler, flexible cord, and wall plug must bear a "T" mark and registration
number in accordance with the Japanese Dentori Law. Flexible cord must be Type VCT or
VCTF, 3-conductor, 1.0 mm
2
conductor size. Wall plug must be a two-pole grounding type
with a Japanese Industrial Standard C8303 (7A, 125V) configuration.