1783 Slot x Drive Array Controller Failure. If this message appears immediately following a
ROM installation, the ROM is defective or not
installed properly. Check that the controller is
firmly inserted in its slot. Check for improper
cabling or SCSI ID conflicts. Try upgrading the
System ROMs. Otherwise, replace the Smart
Array 431 Controller.
1784 Slot x Drive Array Drive Failure. The following
SCSI drive(s) should be replaced: SCSI port (
y
)
SCSI ID (
x
)
Check for loose cables. Replace defective drive
x
and/or cable(s).
1785 Slot 1 Drive Array not Configured (followed by
one of the following):
(1) Run Compaq Array Configuration Utility
(2) No drives detected
(3) Drive positions appear to have changed -
Run Drive Array Advanced Diagnostics if
previous positions are unknown. Then turn
system power OFF and move drives to their
original positions.
(4) Configuration information indicates drive
positions beyond the capability of this
controller. This may be due to drive
movement from a controller that supports
more drives than the current controller.
(5) Configuration information indicates drives
were configured on a controller with a newer
firmware version.
(RESUME = F1 KEY)
(1) Run the Compaq Array Configuration Utility.
(2) Turn off system and check SCSI cable
connections to make sure drives are attached
properly.
(3) Run Drive Array Advanced Diagnostics if
previous positions are unknown. Then turn
system power OFF and move drives to their
original positions.
(4) To avoid data loss, turn system power OFF
and reattach drives to the original controller.
(5) To avoid data loss, reattach drives to the
original controller or upgrade the controller
firmware to the version on the original controller
using Option ROMPaq.
Select F1 key to resume.