The Smart Array 431 Controller produces diagnostic error messages at reboot.
Many of these Power-On Self-Test (POST) messages are self-explanatory and
suggest corrective actions for troubleshooting. Detailed information and
corrective actions are listed below.
1720 Slot x Drive Array – S.M.A.R.T. Hard Drive
Detects Imminent Failure: SCSI Port x: SCSI
ID x
The indicated drive has reported a S.M.A.R.T.
predictive-failure condition. It may fail at some
time in the future.
Back up data before
replacing drive(s) if using RAID 0 fault-tolerance
level.
1721 Slot x Drive Array – Drive Parameter Tracking
Predicts Imminent Failure
The following device(s) should be replaced
when conditions permit:
! Back up data before
replacing drive(s) if using RAID 0 fault-tolerance
level.
MAP Threshold exceeded condition.
1724 Slot x Drive Array - Physical Drive Position
Change(s) Detected - Logical drive
configuration has automatically been
updated. (RESUME = F1 KEY)
This message indicates that logical drive
configuration has been updated automatically
following physical drive position changes.
Select key to resume.