Compaq HSG80 - StorageWorks RAID Array Controller Especificações Página 72

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 71
2–44 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
12. Press Return to resume device port activity and restart the “other controller.” When all
port activity has restarted, The following display appears:
PVA replacement complete.
Please wait . . .
If the other controller did not restart, press its reset button.
Field Replacement Utility terminated.
13. If the “other controller” did not restart, press its reset button.
14. Enable failover and re-establish the dual-redundant configuration with the following
command:
SET FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystems configuration from “this controller” to the
“other controller.”
15. Disconnect the PC or terminal from the controller maintenance port.
Vista de página 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 295 296

Comentários a estes Manuais

Sem comentários