Upgrading the Subsystem 3–17
14. Enable failover, and establish the dual-redundant controller configuration with the
following command:
SET FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystem configuration from “this controller” to the new
controller.
15. See the Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 CLI
Reference Guide to configure the controller.
16. Disconnect the PC or terminal from the controller maintenance port.
Upgrading Cache Memory
Use Figure 3–4 and Table 3–1 to configure the cache module.
Figure 3–4. Cache module DIMM locations
CXO6576B
4
2
3
1