Compaq HSG80 - StorageWorks RAID Array Controller Especificações Página 44

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 43
2–16 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
8. If not already connected, connect a PC or terminal to the controller maintenance port.
9. Restart the controller by pressing its reset button.
10. When the CLI prompt reappears, display details about the configured controller using
the following command:
SHOW THIS_CONTROLLER FULL
11. Mount the logical units on the host. If using a Windows NT platform, restart the server.
12. Set the subsystem date and time using the following command in its entirety:
SET THIS_CONTROLLER TIME=
dd-mmm-yyyy:hh:mm:ss
13. Disconnect the PC or terminal from the controller maintenance port.
Vista de página 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 295 296

Comentários a estes Manuais

Sem comentários