HP ProLiant SL250s Gen8 Server User Guide Abstract This document provides detailed instructions to configure and use the HP ProLiant SL250s Gen8 Ser
Component identification 10 Item Description 4 SATA hard drive connector 2 5 System battery 6 Processor socket 2 7 Processor 2 DIMM slots 8 Power c
Index 100 S safety considerations 19, 71 safety information 71 SAS cabling 45 SAS drive numbers 12 SAS hard drive 45 SATA drive numbers
Component identification 11 The arrow points to the front of the node. System maintenance switch Position Default Function S1 Off Off = iLO 4 s
Component identification 12 NMI header The NMI header enables administrators to perform a memory dump before performing a hard reset. Crash dump ana
Component identification 13 • Rear SFF hard drive bay numbers (box 0) Drive LED definitions Item LED Status Definition 1 Locate Solid b
Component identification 14 Item LED Status Definition Off The drive is not configured by a RAID controller.
Operations 15 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the node Before powering down th
Operations 16 3. Remove the server from the chassis (on page 15). 4. Place the node on a flat, level work surface. Remove the processor air baffl
Setup 17 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and
Setup 18 Space and airflow requirements To allow for servicing and adequate airflow, observe the following space and airflow requirements when decid
Setup 19 Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties
Setup 20 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extended to the floor.
Setup 21 Installing components WARNING: The node is very heavy. To reduce the risk of personal injury or damage to the equipment: • Reduce the
Setup 22 3. Connect peripheral devices to the server. Item Description 1 Hot-plug hard drive, Bay 1 HDD 1 2 Hot-plug hard drive, Bay 1 HDD 2 3 Op
Setup 23 Powering up the chassis Connect the AC or DC power cables, depending on the power configuration. When the circuit breakers are powered, the
Hardware options installation 24 Hardware options installation Introduction If more than one option is being installed, read the installation instru
Hardware options installation 25 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system compon
Hardware options installation 26 8. Remove the clear processor socket cover. Retain the processor socket cover for future use. 9. Install the proc
Hardware options installation 27 CAUTION: Do not press down on the processor. Pressing down on the processor may cause damage to the processor s
Hardware options installation 28 13. Install the heatsink. 14. Install the air baffle. 15. Install the server into the chassis. 16. Power up the
Hardware options installation 29 while the industry supports DDR3-1333 RDIMM at 1.5V, this Gen8 server supports DDR3-1333 RDIMM at 1.35V. This diffe
Contents 3 Contents Component identification ...
Hardware options installation 30 DIMM identification To determine DIMM characteristics, use the label attached to the DIMM and the following illustr
Hardware options installation 31 is degrading. This configuration enables DIMMs that have a higher probability of receiving an uncorrectable memory
Hardware options installation 32 contents of the degraded rank to the online spare rank. The node then deactivates the failing rank and automaticall
Hardware options installation 33 • Each populated channel must have a spare rank. A single dual-rank DIMM is not a valid configuration. Lockstep M
Hardware options installation 34 9. Install the server into the chassis ("Installing the server into the chassis" on page 21). 10. Power
Hardware options installation 35 2. Prepare the drive. 3. Install the drive. 4. Determine the status of the drive from the drive LED definitions
Hardware options installation 36 3. Remove the front GPU cage. 4. Remove the GPU bracket.
Hardware options installation 37 5. Attach the mini-SAS cable to the rear SAS port on the system board. 6. Attach the power connectors to the pers
Hardware options installation 38 o Front GPU cage o Top rear GPU cage 9. Using the eight T-15 screws included in this kit, attach the SFF cable
Hardware options installation 39 o Front drive cage o Rear drive cage 10. Install the quick-release drives in the front and rear drive cages (&q
Contents 4 General DIMM slot population guidelines ... 32 Inst
Hardware options installation 40 o Left node o Right node 12. Install the front GPU cage. 13. Install the server into the chassis ("Instal
Hardware options installation 41 4. Install the quick-release drive. 5. Install the server into the chassis ("Installing the server into the
Hardware options installation 42 CAUTION: After the node is powered down, wait 15 seconds and then check the amber LED before unplugging the cable
Hardware options installation 43 Installing the FBWC capacitor pack WARNING: To reduce the risk of personal injury from hot surfaces, allow the
Hardware options installation 44 o HP ProLiant SL250s Gen8 Server, left node o HP ProLiant SL250s Gen8 Server, right node
Hardware options installation 45 9. Connect the FBWC cable to the cache module on the system board or to the controller card. 10. Install the serv
Hardware options installation 46 3. Remove the HDD cage. 4. Remove the front GPU.
Hardware options installation 47 5. Remove the bracket. 6. Remove the PCI cage. 7. Install the controller card into the PCI cage
Hardware options installation 48 8. Connect the mini-SAS cable included in this kit to the controller card. 9. Install the PCI cage in the server.
Hardware options installation 49 14. Connect the mini-SAS cable included in this kit to the HDD cage. 15. Route the mini-SAS cable from the HDD ca
Contents 5 HP Technology Service Portfolio ... 73
Hardware options installation 50 o Right node 16. Install the server into the chassis ("Installing the server into the chassis" on page
Hardware options installation 51 5. Install the expansion board into the slot until it seats firmly. To install an expansion board in PCI expansion
Hardware options installation 52 4. Install the PCI riser board assembly. IMPORTANT: The server does not power up if the PCI riser board assemb
Hardware options installation 53 6. Power up the server (on page 15). Redundant hot-plug power supply option CAUTION: All power supplies insta
Hardware options installation 54 3. Remove the protective cover from the connector pins on the power supply. WARNING: To reduce the risk of ele
Hardware options installation 55 6. Use the strain relief clip from the server hardware kit to secure the power cord. 7. Route the power cord thro
Hardware options installation 56 Item Connector Description 3 Video For connecting a video monitor 4 USB For connecting up to two USB devices 5
Hardware options installation 57 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system compon
Hardware options installation 58 9. Slide the node into the rack. 10. Power up the node ("Power up the server" on page 15). Retaining th
Cabling 59 Cabling Cabling overview This section provides guidelines that help you make informed decisions about cabling the server and hardware opt
Component identification 6 Component identification Front panel components Item Description 1 Hot-plug hard drive, Bay 1 HDD 1 2 Hot-plug hard dr
Cabling 60 HP ProLiant SL250s Gen8 Server, right node Front GPU cabling The following figures depict the power cable and throttling cable connecti
Cabling 61 • Right node
Software and configuration utilities 62 Software and configuration utilities Server mode The software and configuration utilities presented in this
Software and configuration utilities 63 iLO 4 enables and manages the Active Health System (on page 63) and also features Agentless Management. All
Software and configuration utilities 64 The Active Health System log, in conjunction with the system monitoring provided by Agentless Management or
Software and configuration utilities 65 This functionality supports operating systems that are supported by the node. For operating systems supporte
Software and configuration utilities 66 SPP has several key features for updating HP ProLiant servers. Using HP SUM as the deployment tool, SPP can
Software and configuration utilities 67 Using RBSU To use RBSU, use the following keys: • To access RBSU, press the F9 key during power-up when pro
Software and configuration utilities 68 • Access RBSU by pressing the F9 key. • Access Intelligent Provisioning Maintenance Menu by pressing the F
Software and configuration utilities 69 Utilities and features Array Configuration Utility ACU is a utility with the following features: • Runs as
Component identification 7 Front panel LEDs and buttons Item Description Status 1 Power On/Standby button and system power LED Green—System on A
Software and configuration utilities 70 Option ROM Configuration for Arrays Before installing an operating system, you can use the ORCA utility to c
Software and configuration utilities 71 Legacy USB support provides USB functionality in environments where USB support is not available normally. S
Software and configuration utilities 72 Software and firmware Software and firmware should be updated before using the server for the first time, un
Software and configuration utilities 73 HP Technology Service Portfolio HP Technology Services offers a targeted set of consultancy, deployment, and
Troubleshooting 74 Troubleshooting Troubleshooting resources The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedur
System battery 75 System battery If the server no longer automatically displays the correct date and time, you might have to replace the battery tha
Regulatory compliance notices 76 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance
Regulatory compliance notices 77 radio communications. However, there is no guarantee that interference will not occur in a particular installation.
Regulatory compliance notices 78 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. C
Regulatory compliance notices 79 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other
Component identification 8 Rear panel components The server has four power supplies, eight fans, and a single SLAPM interface located on the rear pa
Regulatory compliance notices 80 Class B equipment Chinese notice Class A equipment Vietnam compliance marking notice This marking is for applic
Regulatory compliance notices 81 WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the
Regulatory compliance notices 82 Acoustics statement for Germany (Geräuschemission) Schalldruckpegel LpA < 70 dB(A) Zuschauerpositionen (bystand
Electrostatic discharge 83 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo
Specifications 84 Specifications Environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°F) Shi
Support and other resources 85 Support and other resources Before you contact HP Be sure to have the following information available before you call
Support and other resources 86 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship
Support and other resources 87 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in
Support and other resources 88 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,
Support and other resources 89 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes
Component identification 9 Item Description Status Flashing blue—System is being remotely managed. Off—Deactivated 4 Fan 4/12 power LED Off—Norma
Support and other resources 90 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel
Support and other resources 91
Support and other resources 92
Acronyms and abbreviations 93 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADM Advanced Data Mirroring AMP Advan
Acronyms and abbreviations 94 GPU graphics processing unit HDD hard drive HP SIM HP Systems Insight Manager HP SUM HP Smart Update Manager IEC I
Acronyms and abbreviations 95 POST Power-On Self Test RBSU ROM-Based Setup Utility RDIMM registered dual in-line memory module RDP Rapid Deployme
Acronyms and abbreviations 96 TPM Trusted Platform Module UDIMM unregistered dual in-line memory module UID unit identification USB universal ser
Documentation feedback 97 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat
Index 98 A ACU (Array Configuration Utility) 62, 69 Advanced ECC memory 31, 32, 68 air baffle 16 airflow requirements 17, 18 Array Configura
Index 99 HP Smart memory 28 I identification number 76 iLO (Integrated Lights-Out) 62, 63, 64 IML (Integrated Management Log) 62, 64 Insight
Comentários a estes Manuais