Compaq ProLiant SL250s Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Servidores Compaq ProLiant SL250s. Compaq ProLiant SL250s User guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
HP ProLiant SL250s Gen8 Server
User Guide
Abstract
This document provides detailed instructions to configure and use the HP ProLiant SL250s Gen8 Server.
Part Number: 666298-002
September 2012
Edition: 2
Vista de página 0
1 2 3 4 5 6 ... 99 100

Resumo do Conteúdo

Página 1 - User Guide

HP ProLiant SL250s Gen8 Server User Guide Abstract This document provides detailed instructions to configure and use the HP ProLiant SL250s Gen8 Ser

Página 2

Component identification 10 Item Description 4 SATA hard drive connector 2 5 System battery 6 Processor socket 2 7 Processor 2 DIMM slots 8 Power c

Página 3 - Contents

Index 100 S safety considerations 19, 71 safety information 71 SAS cabling 45 SAS drive numbers 12 SAS hard drive 45 SATA drive numbers

Página 4 - Contents 4

Component identification 11 The arrow points to the front of the node. System maintenance switch Position Default Function S1 Off Off = iLO 4 s

Página 5 - Contents 5

Component identification 12 NMI header The NMI header enables administrators to perform a memory dump before performing a hard reset. Crash dump ana

Página 6 - Component identification

Component identification 13 • Rear SFF hard drive bay numbers (box 0) Drive LED definitions Item LED Status Definition 1 Locate Solid b

Página 7 - Front panel LEDs and buttons

Component identification 14 Item LED Status Definition Off The drive is not configured by a RAID controller.

Página 8 - Rear panel LEDs and buttons

Operations 15 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the node Before powering down th

Página 9 - System board components

Operations 16 3. Remove the server from the chassis (on page 15). 4. Place the node on a flat, level work surface. Remove the processor air baffl

Página 10 - DIMM slot locations

Setup 17 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and

Página 11 - System maintenance switch

Setup 18 Space and airflow requirements To allow for servicing and adequate airflow, observe the following space and airflow requirements when decid

Página 12 - Device numbers

Setup 19 Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of

Página 13 - Drive LED definitions

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Página 14 - Component identification 14

Setup 20 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extended to the floor.

Página 15 - Operations

Setup 21 Installing components WARNING: The node is very heavy. To reduce the risk of personal injury or damage to the equipment: • Reduce the

Página 16

Setup 22 3. Connect peripheral devices to the server. Item Description 1 Hot-plug hard drive, Bay 1 HDD 1 2 Hot-plug hard drive, Bay 1 HDD 2 3 Op

Página 17 - Rack planning resources

Setup 23 Powering up the chassis Connect the AC or DC power cables, depending on the power configuration. When the circuit breakers are powered, the

Página 18 - Temperature requirements

Hardware options installation 24 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Página 19 - Rack warnings

Hardware options installation 25 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system compon

Página 20 - Installing options

Hardware options installation 26 8. Remove the clear processor socket cover. Retain the processor socket cover for future use. 9. Install the proc

Página 21 - Installing components

Hardware options installation 27 CAUTION: Do not press down on the processor. Pressing down on the processor may cause damage to the processor s

Página 22

Hardware options installation 28 13. Install the heatsink. 14. Install the air baffle. 15. Install the server into the chassis. 16. Power up the

Página 23 - Registering the server

Hardware options installation 29 while the industry supports DDR3-1333 RDIMM at 1.5V, this Gen8 server supports DDR3-1333 RDIMM at 1.35V. This diffe

Página 24 - Processor option

Contents 3 Contents Component identification ...

Página 25

Hardware options installation 30 DIMM identification To determine DIMM characteristics, use the label attached to the DIMM and the following illustr

Página 26

Hardware options installation 31 is degrading. This configuration enables DIMMs that have a higher probability of receiving an uncorrectable memory

Página 27

Hardware options installation 32 contents of the degraded rank to the online spare rank. The node then deactivates the failing rank and automaticall

Página 28 - Memory options

Hardware options installation 33 • Each populated channel must have a spare rank. A single dual-rank DIMM is not a valid configuration. Lockstep M

Página 29

Hardware options installation 34 9. Install the server into the chassis ("Installing the server into the chassis" on page 21). 10. Power

Página 30 - Memory configurations

Hardware options installation 35 2. Prepare the drive. 3. Install the drive. 4. Determine the status of the drive from the drive LED definitions

Página 31

Hardware options installation 36 3. Remove the front GPU cage. 4. Remove the GPU bracket.

Página 32

Hardware options installation 37 5. Attach the mini-SAS cable to the rear SAS port on the system board. 6. Attach the power connectors to the pers

Página 33 - Installing a DIMM

Hardware options installation 38 o Front GPU cage o Top rear GPU cage 9. Using the eight T-15 screws included in this kit, attach the SFF cable

Página 34 - Drive guidelines

Hardware options installation 39 o Front drive cage o Rear drive cage 10. Install the quick-release drives in the front and rear drive cages (&q

Página 35

Contents 4 General DIMM slot population guidelines ... 32 Inst

Página 36 - Remove the GPU bracket

Hardware options installation 40 o Left node o Right node 12. Install the front GPU cage. 13. Install the server into the chassis ("Instal

Página 37

Hardware options installation 41 4. Install the quick-release drive. 5. Install the server into the chassis ("Installing the server into the

Página 38 - Top rear GPU cage

Hardware options installation 42 CAUTION: After the node is powered down, wait 15 seconds and then check the amber LED before unplugging the cable

Página 39

Hardware options installation 43 Installing the FBWC capacitor pack WARNING: To reduce the risk of personal injury from hot surfaces, allow the

Página 40

Hardware options installation 44 o HP ProLiant SL250s Gen8 Server, left node o HP ProLiant SL250s Gen8 Server, right node

Página 41 - Controller options

Hardware options installation 45 9. Connect the FBWC cable to the cache module on the system board or to the controller card. 10. Install the serv

Página 42 - Installing the cache module

Hardware options installation 46 3. Remove the HDD cage. 4. Remove the front GPU.

Página 43

Hardware options installation 47 5. Remove the bracket. 6. Remove the PCI cage. 7. Install the controller card into the PCI cage

Página 44

Hardware options installation 48 8. Connect the mini-SAS cable included in this kit to the controller card. 9. Install the PCI cage in the server.

Página 45

Hardware options installation 49 14. Connect the mini-SAS cable included in this kit to the HDD cage. 15. Route the mini-SAS cable from the HDD ca

Página 46 - Remove the front GPU

Contents 5 HP Technology Service Portfolio ... 73

Página 47 - Remove the PCI cage

Hardware options installation 50 o Right node 16. Install the server into the chassis ("Installing the server into the chassis" on page

Página 48

Hardware options installation 51 5. Install the expansion board into the slot until it seats firmly. To install an expansion board in PCI expansion

Página 49 - Left node

Hardware options installation 52 4. Install the PCI riser board assembly. IMPORTANT: The server does not power up if the PCI riser board assemb

Página 50 - Expansion board options

Hardware options installation 53 6. Power up the server (on page 15). Redundant hot-plug power supply option CAUTION: All power supplies insta

Página 51

Hardware options installation 54 3. Remove the protective cover from the connector pins on the power supply. WARNING: To reduce the risk of ele

Página 52

Hardware options installation 55 6. Use the strain relief clip from the server hardware kit to secure the power cord. 7. Route the power cord thro

Página 53

Hardware options installation 56 Item Connector Description 3 Video For connecting a video monitor 4 USB For connecting up to two USB devices 5

Página 54

Hardware options installation 57 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system compon

Página 55 - Connecting the SUV cable

Hardware options installation 58 9. Slide the node into the rack. 10. Power up the node ("Power up the server" on page 15). Retaining th

Página 56

Cabling 59 Cabling Cabling overview This section provides guidelines that help you make informed decisions about cabling the server and hardware opt

Página 57

Component identification 6 Component identification Front panel components Item Description 1 Hot-plug hard drive, Bay 1 HDD 1 2 Hot-plug hard dr

Página 58

Cabling 60 HP ProLiant SL250s Gen8 Server, right node Front GPU cabling The following figures depict the power cable and throttling cable connecti

Página 59 - Cabling

Cabling 61 • Right node

Página 60 - Front GPU cabling

Software and configuration utilities 62 Software and configuration utilities Server mode The software and configuration utilities presented in this

Página 61 - • Right node

Software and configuration utilities 63 iLO 4 enables and manages the Active Health System (on page 63) and also features Agentless Management. All

Página 62 - HP iLO Management Engine

Software and configuration utilities 64 The Active Health System log, in conjunction with the system monitoring provided by Agentless Management or

Página 63 - Active Health System

Software and configuration utilities 65 This functionality supports operating systems that are supported by the node. For operating systems supporte

Página 64 - Intelligent Provisioning

Software and configuration utilities 66 SPP has several key features for updating HP ProLiant servers. Using HP SUM as the deployment tool, SPP can

Página 65 - HP Service Pack for ProLiant

Software and configuration utilities 67 Using RBSU To use RBSU, use the following keys: • To access RBSU, press the F9 key during power-up when pro

Página 66 - HP ROM-Based Setup Utility

Software and configuration utilities 68 • Access RBSU by pressing the F9 key. • Access Intelligent Provisioning Maintenance Menu by pressing the F

Página 67 - Boot options

Software and configuration utilities 69 Utilities and features Array Configuration Utility ACU is a utility with the following features: • Runs as

Página 68 - Configuring AMP modes

Component identification 7 Front panel LEDs and buttons Item Description Status 1 Power On/Standby button and system power LED Green—System on A

Página 69 - Utilities and features

Software and configuration utilities 70 Option ROM Configuration for Arrays Before installing an operating system, you can use the ORCA utility to c

Página 70 - USB support

Software and configuration utilities 71 Legacy USB support provides USB functionality in environments where USB support is not available normally. S

Página 71 - Keeping the system current

Software and configuration utilities 72 Software and firmware Software and firmware should be updated before using the server for the first time, un

Página 72 - ProLiant Servers

Software and configuration utilities 73 HP Technology Service Portfolio HP Technology Services offers a targeted set of consultancy, deployment, and

Página 73

Troubleshooting 74 Troubleshooting Troubleshooting resources The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedur

Página 74 - Troubleshooting

System battery 75 System battery If the server no longer automatically displays the correct date and time, you might have to replace the battery tha

Página 75 - System battery

Regulatory compliance notices 76 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Página 76 - FCC rating label

Regulatory compliance notices 77 radio communications. However, there is no guarantee that interference will not occur in a particular installation.

Página 77 - Modifications

Regulatory compliance notices 78 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. C

Página 78 - • EMC Directive 2004/108/EC

Regulatory compliance notices 79 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other

Página 79 - Korean notice

Component identification 8 Rear panel components The server has four power supplies, eight fans, and a single SLAPM interface located on the rear pa

Página 80 - Laser compliance

Regulatory compliance notices 80 Class B equipment Chinese notice Class A equipment Vietnam compliance marking notice This marking is for applic

Página 81 - Battery replacement notice

Regulatory compliance notices 81 WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the

Página 82 - < 70 dB(A)

Regulatory compliance notices 82 Acoustics statement for Germany (Geräuschemission) Schalldruckpegel LpA < 70 dB(A) Zuschauerpositionen (bystand

Página 83 - Electrostatic discharge

Electrostatic discharge 83 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Página 84 - Specifications

Specifications 84 Specifications Environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°F) Shi

Página 85 - Support and other resources

Support and other resources 85 Support and other resources Before you contact HP Be sure to have the following information available before you call

Página 86

Support and other resources 86 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Página 87 - Customer Self Repair

Support and other resources 87 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Página 88

Support and other resources 88 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Página 89 - Reparo feito pelo cliente

Support and other resources 89 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Página 90

Component identification 9 Item Description Status Flashing blue—System is being remotely managed. Off—Deactivated 4 Fan 4/12 power LED Off—Norma

Página 91

Support and other resources 90 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Página 92

Support and other resources 91

Página 93 - Acronyms and abbreviations

Support and other resources 92

Página 94

Acronyms and abbreviations 93 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADM Advanced Data Mirroring AMP Advan

Página 95

Acronyms and abbreviations 94 GPU graphics processing unit HDD hard drive HP SIM HP Systems Insight Manager HP SUM HP Smart Update Manager IEC I

Página 96

Acronyms and abbreviations 95 POST Power-On Self Test RBSU ROM-Based Setup Utility RDIMM registered dual in-line memory module RDP Rapid Deployme

Página 97 - Documentation feedback

Acronyms and abbreviations 96 TPM Trusted Platform Module UDIMM unregistered dual in-line memory module UID unit identification USB universal ser

Página 98 - Index 98

Documentation feedback 97 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Página 99 - Index 99

Index 98 A ACU (Array Configuration Utility) 62, 69 Advanced ECC memory 31, 32, 68 air baffle 16 airflow requirements 17, 18 Array Configura

Página 100 - Index 100

Index 99 HP Smart memory 28 I identification number 76 iLO (Integrated Lights-Out) 62, 63, 64 IML (Integrated Management Log) 62, 64 Insight

Comentários a estes Manuais

Sem comentários