Compaq DL585 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Servidores Compaq DL585. Compaq DL585 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 46
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Hot Plug Redundant Fans (standard)
1.
Redundant hot-plug power supply (optional)
2.
System Insight Display
2.
PCI Express and PCI-X expansion slots
3.
Hot Plug Redundant Fans (standard)
3.
Hot-plug power supply (primary)
4.
1.44 MB Diskette Drive (optional)
4.
T-15 Torx screwdriver
5.
DVD/CD-RW drive (standard)
5.
NIC connector 2
6.
Front Panel LED Display (internal and external health, Unit
ID light) and Power Button
6.
NIC connector 1
7.
Integrated Lights-Out 2 (iLO 2) connector
7.
Two USB ports
8.
Serial connector
8.
One video port
9.
USB connectors (two)
9.
Front accessible processor / memory cage
10.
Mouse connector
10.
Eight bay Small Form Factor (SFF) Serial Attached SCSI
(SAS) drive cage
11.
Keyboard connector
12.
Video connector
11.
4U (7" Height) Rack Form Factor
13.
Rear UID button and LED
12.
Hot Plug Redundant Power Supply
13.
Nine PCI I/O Slots (2 64-bit/100MHz PCI-X, 4 PCI-Express
x4, 3 PCI-Express x8)
14.
Hot Plug Redundant Power Supply
15.
Removable Top Access Panel
What's New
What's NewWhat's New
What's New
Upgrade options now available for Quad-Core 8300 series AMD processors
QuickSpecs
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
Overview
DA - 12575 Canada — Version 37 — May 28, 2008
Page 1
Vista de página 0
1 2 3 4 5 6 ... 45 46

Resumo do Conteúdo

Página 1 - QuickSpecs

Front View:Front View:Front View:Front View:Rear View:Rear View:Rear View:Rear View:1.Hot Plug Redundant Fans (standard)1.Redundant hot-plug power sup

Página 2

ServiceabilityServiceabilityServiceabilityServiceabilitySystem Insight Display - precisely depicts all major subsystems of the server (PCI I/O, Memory

Página 3

Required CablingRequired CablingRequired CablingRequired CablingFor required cabling information, refer to the HP Web site at: www.hp.com/servers/dl58

Página 4

Rack MountingRack MountingRack MountingRack MountingRequirementsRequirementsRequirementsRequirementsHP ProLiant DL585 G2 rack models provide tool-free

Página 5

Support: 3-Year Support Plus 24 onlyRefer to the information on "Installation & Start-Up" for service on ProLiant server and Microsoft o

Página 6

SolutionsSolutionsSolutionsSolutionsDesigned for enterprise customers with growing data centers and application and Internet serviceproviders that req

Página 7

ModelsModelsModelsModelsDL585R02 O3.0GHz-1DL585R02 O3.0GHz-1DL585R02 O3.0GHz-1DL585R02 O3.0GHz-1MB, 8 GB, 120WMB, 8 GB, 120WMB, 8 GB, 120WMB, 8 GB, 12

Página 8

DL585R02 O2.8GHz-1DL585R02 O2.8GHz-1DL585R02 O2.8GHz-1DL585R02 O2.8GHz-1MB, 8 GB, 120WMB, 8 GB, 120WMB, 8 GB, 120WMB, 8 GB, 120W(4P Dual-Core)413930-0

Página 9

DL585R02 O2.4 GHz-1DL585R02 O2.4 GHz-1DL585R02 O2.4 GHz-1DL585R02 O2.4 GHz-1MB, 2 GB, 95WMB, 2 GB, 95WMB, 2 GB, 95WMB, 2 GB, 95W(2P Dual- core)413928-

Página 10

NOTE: NOTE: NOTE: NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only validconfigurations are

Página 11

Storage ControllersStorage ControllersStorage ControllersStorage ControllersHP Smart Array P800/512 BBWC Controller381513-B21HP Smart Array P600/256 B

Página 12

At A GlanceAt A GlanceAt A GlanceAt A GlanceThe HP ProLiant DL585 G2 supports the AMD 8000 processors, enabling a huge boost in performance over singl

Página 13

NOTE:NOTE:NOTE:NOTE: Some options may not be factory integratable. Please contact your local sales representative for additionalinformation. HP ProLia

Página 14

Software Technical Support and Update Service. One certificate is shipped for eachlicense.NOTE: NOTE: NOTE: NOTE: For additional License Kits, please

Página 15

ProLiant Essentials Integrated Lights-Out Select Pack, No Media, 1-Server LicenseNOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the Q

Página 16

ProcessorsProcessorsProcessorsProcessorsAMD Opteron™ 8356, Quad-Core Processor (2.3 GHz, 75W ACP) 2P Option KitNOTE: NOTE: NOTE: NOTE: Upgrading to 83

Página 17

Hard DrivesHard DrivesHard DrivesHard DrivesSFF SATA Hard Disk Drives – Hot PlugSFF SATA Hard Disk Drives – Hot PlugSFF SATA Hard Disk Drives – Hot Pl

Página 18

HP Smart Array P400/512 MB BBWC ControllerNOTE: NOTE: NOTE: NOTE: The Smart Array P400 Controller supports internal Serial Attached SCSI andSerial ATA

Página 19

CommunicationsCommunicationsCommunicationsCommunicationsHP NC110T PCI Express Gigabit Server Adapter434905-B21HP NC360T PCI Express Dual Port Gigabit

Página 20

HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape DriveNOTE: NOTE: NOTE: NOTE: HP recommends combining this tape drive with the 1U SAS Rack-Mount ki

Página 21

HP D2D Backup SystemHP D2D Backup SystemHP D2D Backup SystemHP D2D Backup SystemHP StorageWorks D2D110 Backup SystemNOTE: NOTE: NOTE: NOTE: 1TB of Dis

Página 22

NOTE: NOTE: NOTE: NOTE: Please reference the MSL2024, MSL4048, MSL8096 and MSL6000 TapeLibrary QuickSpecs at: http://www.hp.com/go/automation for addi

Página 23

NOTE: NOTE: NOTE: NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities andspecific

Página 24

HP StorageWorksHP StorageWorksHP StorageWorksHP StorageWorksModular Smart Array 20Modular Smart Array 20Modular Smart Array 20Modular Smart Array 20HP

Página 25

Modular PowerModular PowerModular PowerModular PowerDistribution Units 1U/0UDistribution Units 1U/0UDistribution Units 1U/0UDistribution Units 1U/0U(U

Página 26

NOTE:NOTE:NOTE:NOTE: Please see the Rack 10000 G2 QuickSpecs for Technical Specifications suchas height, width, depth, weight, and colour:http://h1800

Página 27

HP Serial Console ServerHP Serial Console ServerHP Serial Console ServerHP Serial Console ServerOptionsOptionsOptionsOptionsHP 16 Port Serial Console

Página 28

NOTE: NOTE: NOTE: NOTE: Memory configurations listed do not apply to "Factory Integrated Models."HP ProLiant DL585 G2 2P ModelsHP ProLiant D

Página 29

Standard Memory ConfigurationStandard Memory ConfigurationStandard Memory ConfigurationStandard Memory Configuration (2.8GHz models)Total Memory = 8 G

Página 30

AEjectable: Slimline Diskette or Optical Drive (Optional)BEjectable: Slimline Optical Drive (DVD/CD-RWStandard)1-8SFF SAS Internal Drive cage Drive Su

Página 31

External StorageExternal StorageExternal StorageExternal Storage QuantityQuantityQuantityQuantitySupportedSupportedSupportedSupportedPositionPositionP

Página 32

HP StorageWorks USBHP StorageWorks USBHP StorageWorks USBHP StorageWorks USBTape Drives, ExternalTape Drives, ExternalTape Drives, ExternalTape Drives

Página 33

HP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DBackup SystemsBackup SystemsBackup SystemsBackup SystemsD2D110D2D120D2D130

Página 34

Expansion SlotsExpansion SlotsExpansion SlotsExpansion SlotsExpansionExpansionExpansionExpansionSlot #Slot #Slot #Slot #TechnologyTechnologyTechnology

Página 35

Part numberPart numberPart numberPart number348114-001Operational Input Voltage RangeOperational Input Voltage RangeOperational Input Voltage RangeOpe

Página 36

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm

Página 37

AltitudeAltitudeAltitudeAltitudeOperating3050 m (10,000 ft). This value may be limitedby the type and number of options installed.Maximum allowable al

Página 38

Stop TimeStop TimeStop TimeStop Time< 4seconds Laser ParametersLaser ParametersLaser ParametersLaser ParametersTypeSemiconductor Laser GaA1AsWave L

Página 39

2352, 2340, 2336,2048 bytes(Mode-2)Diameter120 mm, 80 mm (with adapter at verticalmounting mode)Loading MechanismLoading MechanismLoading MechanismLoa

Página 40

Power Regulator ControlDedicated LAN ConnectivitySecure access using web browserSecure access using Secure Shell (SSH) clientSerial connectivityAutoma

Página 41

Two embedded NC371iTwo embedded NC371iTwo embedded NC371iTwo embedded NC371iMultifunction GigabitMultifunction GigabitMultifunction GigabitMultifuncti

Página 42

StorageStorageStorageStorageDiskette DriveOptional 1.44 MB Diskette Drive (slimline) - ejectable for security andserviceabilityOptical DriveSlimline D

Página 43

NOTE: NOTE: NOTE: NOTE: Server Migration Pack - Universal Edition can be installed from the SMP Universal CD includedin the Insight Control Management

Página 44

ProLiant EssentialsAccelerated iSCSI PackEnables the embedded Multifunction network controller to serve as both aNIC and an iSCSI HBA providing access

Página 45

HP Serviceguard for LinuxHP Serviceguard for LinuxHP Serviceguard for LinuxHP Serviceguard for Linux(SGLX)(SGLX)(SGLX)(SGLX)HP Serviceguard for Linux

Página 46

Remote ManagementRemote ManagementRemote ManagementRemote ManagementIntegrated Lights-Out 2 (iLO 2) Standard ManagementVirtual Text Remote Console (pr

Comentários a estes Manuais

Sem comentários