Compaq External RAID Controller & Subsystem Manual do Utilizador Página 245

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 347
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 244
Infortrend10-32
When the new controller is connected, the existing controller will
automatically start initializing the replacement controller (IFT-3102U2G and
above). If the existing controller does not initialize the replacement
controller, execute the "Deassert Reset on Failed Controller" function.
If the replacement has been initialized normally, you may proceed to
examine the system status. From the main menu, select "View and Edit
Peripheral Devices" and then "View Peripheral Device Status" to see that the
new controller is being scanned.
When the scanning has completed, the status will change to "Enabled."
Vista de página 244
1 2 ... 240 241 242 243 244 245 246 247 248 249 250 ... 346 347

Comentários a estes Manuais

Sem comentários