Compaq External RAID Controller & Subsystem Manual do Utilizador Página 187

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 347
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 186
Advanced Configurations
9-2
9.1.1 Clone Failing Drive:
Unlike the similar functions combined with S.M.A.R.T., the “Clone
Failing Drive” is a manual function. There are two options for
cloning a failing drive: “Replace after Clone” and “Perpetual
Clone.”
Replace after Clone:
Data on the source drive, the drive with predicted error (or any
selected member drive), will be cloned to a standby spare and
replaced later by the spare. The status of the replaced drive, the
original member drive with predicted error, will be redefined as an
“used drive.” System administrators may replace the used drive
with a new one, and then configure the new drive as a spare drive.
Locate the logical drive to which the specific member drive with
predictable errors belongs. Select the “clone failing drive” function.
Select “Replace After Clone.” The controller will automatically start
the cloning process using the existing “stand-by” (dedicated/global
spare drive) to clone the source drive (the target member drive with
predicted errors). If there is no standby drive (local/global spare
drive), you need to add a new drive and configure it as a standby
drive.
The cloning process will begin with a notification message. Press
[ESC] to proceed.
Vista de página 186
1 2 ... 182 183 184 185 186 187 188 189 190 191 192 ... 346 347

Comentários a estes Manuais

Sem comentários