Consolidating Multi-SMC/AS Configurations to One SMC 7-25
1. Start ConsoleWorks from the SMC desktop. The Show Consoles screen
displays.
2. At the top of the Show Consoles screen select Add Console. The Add Console
screen displays.
NOTE: If the addition is such that there are more than 8 consoles, you
need to have the appropriate licenses, as noted in Chapter 1.
3. From the Type dropdown menu select Telnet. Click the Add Console button.
The Add Telnet Console screen displays (Figure 7–22). Enter the
information requested for the console.
4. Enter a name and a description for the console. The console name must be
unique. (Tip: One way to select unique names is to use the original name
as copied in Section 7.2, and add the system name to it. For example,
ASGS1_Console1.)
5. Select Yes in the Logged box. In the block to the right of the list box enter
D:\Cwks\Log.
6. In the IP Host block enter the IP address that was chosen in Section 7.4.2.
7. In the IP Port block enter the port number copied in Section 7.2
8. Do not select the Raw Data checkbox.
Continuedonpage7-27