Figure 6–5 shows a two-node Fibre Channel cluster with a single RA8000
or ESA12000 storage array with dual-redundant HSG80 controllers and an
DS-SWXHB-07 Fibre Channel hub.
Figure 6–5: Arbitrated Loop Configuration with One Storage Array
ZK-1697U-AI
SWXHB-07
HSG 80
Controller A
HSG 80
Controller B
RA8000/ESA12000
Port 1
Port 2
Port
1
Port 2
KGPSA
Member
System
1
Memory
Channel
KGPSA
Memory
Channel
Memory
Channel
Interface
Member
System
2
6.3.2 Fibre Channel Cluster Configurations for Multiple-Bus Failover
Mode
With multiple-bus failover:
The host controls the failover by accessing units over a different path or
causing the access to the unit to be through the other HSG80 controller.
An active controller causes a failover to the other controller if the
controller recognizes the loss of the switch, hub, or cable to a controller
port.
Each cluster member system has two or more (fabric only) KGPSA host
bus adapters (multiple paths to the storage units).
6–10 Using Fibre Channel Storage
Vista de página 155