Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Manual de Serviço Página 120

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 422
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 119
space. The configuration change is propagated to the other cluster member
systems by entering the following command:
# /sbin/sysconfig -r rm rm_use_512=1
See the Cluster Administration manual for more information on failover
pairs.
The MC2 jumpers are described in Table 5–2.
Table 5–2: MC2 Jumper Configuration
Jumper: Description: Example:
J1: Hub Mode Standard: Pins 1 to 2
123
VH0: Pins 2 to 3
123
VH1: None needed;
store the jumper on
pin 1 or pin 3
123
J3: Window Size 512 MB: Pins 2 to 3
123
128 MB: Pins 1 to 2
123
J4: Page Size 8-KB page size (UNIX):
Pins 1 to 2
123
4-KB page size (not
used): Pins 2 to 3
123
5–4 Setting Up the Memory Channel Cluster Interconnect
Vista de página 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 421 422

Comentários a estes Manuais

Sem comentários