Compaq HSG80 - StorageWorks RAID Array Controller Especificações Página 59

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 396
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 58
2–15
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Table 2–3. Resulting Cache Policies and ECB Status
ECB Status Cache Policy
Cache A Cache B Unmirrored Cache Mirrored Cache
At least
50%
charged
At least
50%
charged
Data loss: No
Cache policy: Both controllers continue
to support write-back caching.
Failover: No
Data loss: No
Cache policy: Both controllers
continue to support write-back
caching.
Failover: No
Less than
50%
charged
At least
50%
charged
Data loss: No
Cache policy: Controller A supports
write-through caching only;
controller B supports write-back
caching.
Failover: In transparent failover, all
units failover to controller B.
In multiple-bus failover with host-
assist, only those units that use write-
back caching, such as RAIDsets and
mirrorsets, failover to controller B.
In single configurations, the controller
only provides write-through caching to
its units.
Data loss: No
Cache policy: Both controllers
continue to support write-back
caching.
Failover: No
Vista de página 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 395 396

Comentários a estes Manuais

Sem comentários