7–55
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
DELETE FAILEDSET
Removes a disk drive from the failedset. The failedset contains disk drives removed
by the controller from RAIDsets and mirrorsets because they failed or were manually
removed using the SET command. Enter the DELETE FAILEDSET command before
physically removing failed disks from the storage shelf for testing, repair, or
replacement.
You should consider all disk drives in the failedset defective. Repair or replace disks
found in the failedset.
Syntax
DELETE FAILEDSET disk-name
Parameter
disk-name
Identifies the disk you want to delete from the failedset. Only one disk at a time can
be removed from a failedset.
Example
To delete DISK20200 from the failedset, use the following command:
DELETE FAILEDSET DISK20200
See also
DELETE container-name
DELETE SPARESET
SET FAILEDSET