The c7000 enclosure is divided into 4 quadrants by the vertical support metalwork. Within each quadrant a removable
divider is used to support half height devices. To install a full-height blade in any quadrant this divider must be removed.
As a consequence a quadrant can only contain either full-height server blades or half-height server blades.
NOTE:
Storage blades and Tape blades can be installed in the same quadrant as both full-height and half-height blades, a
bracket ships with each SB40c/Tape Blade that allows a half-height blade to be mounted on top of the storage blade.
NOTE:
The lower tape or storage blade cannot be removed without first removing the upper half height blade.
HP BladeSystem
c7000 Server Blade
Enclosure
Dimensions
Height
17.4 in (442 mm)
Width
17.6 in (447.04 mm)
Depth
32 in (813 mm)
Shipping Dimensions
Height
29.88 in (759 mm)
Width
23.88 in (607 mm)
Depth
39.88 in (1013 mm)
Single Phase
Enclosure Weight
Unboxed
192 lb (87 kg)
Shipping
235 lb (106.6 kg)
Three -Phase
Enclosure NA/JPN
Weight
Unboxed
222 lb (100.7 kg)
Shipping
265 lb (120.2 kg)
Three-Phase Enclosure
International Weight
Unboxed
222 lb (100.7 kg)
Shipping
265 lb (120.2 kg)
DC Input Enclosure
Weight
Unboxed
151 lb (68.5 kg)
Shipping
194 lb (88 kg)
Max Enclosure Weight
(approximate)
Unboxed
450 lb (204 kg)
Shipping
493 lb (223.6 kg)
Temperature Range
Operating
50° to 95° F (10° to 35° C)
Non-Operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-Operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F)maximum wet bulb temperature,
non-condensing.
NOTE:
Operating temperature has an altitude derating of 1.8° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-
operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is
based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Power
Input Requirements -
Single Phase Model
Rated input frequency
50 to 60 Hz
2400W PSU
Rated input voltage
200 to 240 VAC
Rated input current
per power supply
13.9 A at 200 VAC
13.3 A at 208 VAC
12.6 A at 220 VAC
Rated input power
per power supply
2780 VA
Input Requirements -
Three Phase NA/JPN
Model
Rated input voltage
200 to 208 VAC Line to Line
3-Phase Delta
Rated input frequency
50 to 60 Hz
QuickSpecs
HP BladeSystem c7000 Enclosure
Technical Specifications
DA - 12810 Worldwide QuickSpecs — Version 30 — 6.29.2011