Q
UICK
S
PECS
Options
8 DA-10445-00A-011 — 03.29.2001
Compaq AlphaServer DS20E
Compaq AlphaStation DS20E
Step 7 −
−−
− M-series Cabinets −
−−
− Optional (continued)
Cabinet Configuration Chart for AlphaServer DS20E (5U) with StorageWorks BA370 (20U) and Disk Shelves
• 20U of vertical cabinet space is reserved for one front-mounted BA370 rackmount enclosure, or one front-
mounted and one rear-mounted BA370 enclosure in top of cabinet, front to back. Note that top fan (1U) is
removed from cabinet when BA370 rackmount enclosure is installed.
• Systems and StorageWorks shelves are supported in remaining vertical space; StorageWorks shelves are not
supported in rear of cabinet behind a front-mounted BA370 rackmount enclosure.
Cabinet Rack Kit Cabinet Height/Space Systems BA370 Shelves
H9A10-MC/MD 3X-BA56R-RC 56” / 33U 1 1 (front) or 2
2 2 (front & back) 0
H9A15-MC/MD 3X-BA56R-RC 66.5” / 40U 1 1 (front) or 6
2 2 (front & back) 4
3 0
Note: Installing one BA370 and one system in an H9A15 cabinet requires the mandatory selection of a ballast kit; a
ballast kit is not required if two BA370s and one system are installed in H9A15 cabinet.
M-series Cabinets
67″ cabinet with 56″ or 32U of usable vertical space, 120V dual-24A controller, each with 10 NEMA
5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific; includes rear door and top
fan tray
H9A10-MC
67″ cabinet with 56″ or 32U of usable vertical space, 240V dual-16A controller, each with 12 IEC C13
outlets, input power plug IEC 309, 16A, Europe; includes rear door and top fan tray
H9A10-MD
79″ cabinet with 66.5″ or 39U of usable vertical space, 120V dual-24A controller, each with 10 NEMA
5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific; includes rear door and top
fan tray
H9A15-MC
79″ cabinet with 66.5″ or 39U of usable vertical space, 240V dual-16A controller, each with 12 IEC
C13 outlets, input power plug IEC 309, 16A, Europe; includes rear door and top fan tray
H9A15-MD
Rear Cabinet Extender −
−−
− Required selection of one cabinet extender for each H9A10 or H9A15 cabinet
Rear cabinet extender, top gun blue, for H9A10-MC/MD cabinets
H9C10-TE
Rear cabinet extender, top gun blue, for H9A15-MC/MD cabinets
H9C15-TE
Cabinet Front Door −
−−
− Required selection of door based on cabinet height
Front door, top gun blue, for H9A10-MC/MD cabinet enclosure
H9C10-TF
Front door, top gun blue, for H9A15-MC/MD cabinet enclosure
H9C15-TF
Factory Integration −
−−
− Required
Factory Integration of systems and storage devices assembled and configured in cabinet
enclosure in predefined locations
YS-ASCAA-AA
Ballast Kit −
−−
− Required only if one system is ordered for the H9A15 cabinet
• Ballast is added to a cabinet at particular locations for specific configurations to meet safety regulations for
installation, operation, and service; see Cabinet Configuration Chart
Two 35-40 lb. Steel plates
H9C10-MC
Rackmount Power Cord −
−−
− Required for each system
US/Canada
BN20Z-4E
Non-US
BN35S-4E
Japan, 2.5m
3X-BN46D-4E