Compaq MPAC-18 Especificações Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 9
CHAPTER 2: INSTALLATION
2-2 MAXNET
®
II – MPAC/MPDC Modular Power Supply – Installation & Operation Manual
2.3. DC Redundant Powering of Active MAXNET
®
II Chassis
If more than one power supply is connected to the chassis, the extra power supply acts as a redundant source of power.
Using internal logic within the module (MPAC uses diode steering, MPDC uses load sharing logic) if the main power supply
on the chassis fails, the other power supply becomes the active supplier to the +24 VDC chassis bus rail ensuring power is
always maintained to all active modules in the chassis.
2.4. Remote Powering of Additional Active MAXNET
®
II Chassis’
Both the MPAC and MPDC power supplies include the ability to remotely power additional MAXNET II chassis’ by connecting
bus wire to pin 2 (COM) and 3 (+24V) on the rear terminal block.
* In any of the examples above, be sure to refer to the next section for module power requirements. In any redundant
scenario, if a power supply fails, the load on any remaining power supply must not exceed 8 amps.
Figure #3: Front & Rear Panel Pictures
Figure #4: Remote Powering Figure #5: Redundant Powering
MPAC-110 / MPAC-220
MPDC