the computer, the computer is held level while the allen screws are installed through the bracket. Tighten
the allen screws to 20-25 ft/lbs.
Clearances:
Airflow: Inlets and outlets must have at least 1 inch (25mm) around them and not be obstructed for
adequate airflow to maintain the correct working temperature. In a military environment, the panel into
which the unit is mounted should provide protection from dust.
Cabling: All input/output (I/O) connections are via bottom access. At least 8 inches (20cm) of
unobstructed space is required at the bottom of the computer for unrestricted cable connection. See
figures 9 and 10 for bottom connector panel layout.
Brackets: See figures 3 and 4 for proper clearances for each bracket assembly. An access area of
approximately 4 inches (10 cm) to the sides is required in the area of the allen screws that mount the
computer to the bracket.