Service Guide
EK-HSG80-UP. B01 Page 11
8.0 Removing the HSZ70 Components
Use the following steps to remove the HSZ70 Components:
1. Power-off all the HSZ70 enclosures that will be upgraded at this time.
CAUTION
Electro-Static Discharge (ESD) can easily damage a
controller. Wear a snug-fitting, grounded ESD wrist strap.
2. Remove the SCSI cables from the trilink connector(s) and then remove the trilink
connector(s) from the controller(s).
3. Remove the serial cable from the controller’s maintenance port.
4. Disengage both retaining levers and remove “this controller,” then place it into an antistatic
bag or onto a grounded antistatic mat.
5. Disengage both retaining levers and remove the “other controller,” then place it into an
antistatic bag or onto a grounded antistatic mat.
6. Disengage both retaining levers and partially remove Cache Module A—about half way.
7. Disengage both retaining levers and partially remove Cache Module B—about half way.
8. Disable both External Cache Batteries (ECBs) by pressing their battery disable switches until
the status light stops blinking—about five seconds.
CAUTION
The ECB must be disabled—the status light is not lit or is not
blinking—before disconnecting the ECB cable from the cache
module. Failure to disable the ECB could result cache module
damage.
11. Disconnect the ECB cables from both cache modules, remove the cache modules, and place
them into an antistatic bag or onto a grounded antistatic mat.
12. Disconnect the ECB cables from the ECBs.
13. Remove ECB cables.