Compaq StorageWorks 2/24 - Edge Switch Guia do Utilizador Página 40

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 39
2-18 StorageWorks Fibre Channel Storage Switch Sevice Guide
Probable cause: Failure of G_Port and FL_Port ASIC
Action: Replace Interface module
Probable cause: Failure of interface module
Action: Replace interface module
Probable cause: Failure of GBIC module connector
Action: Replace GBIC module
Feb 12 08:48:29
0000DIAG-DATA, 1, PortX:pass nn
00Frame Tx4>->Rx4 payload byte offset nn is 0xXX sb
0xXX
(CMEM: SOF@ bufline/offset 0xXXXX/0xXX, error @
physical 0xXXXX/0xXX Only one bad byte -- or --
Last bad byte at offset nn.
Probable cause: Failure of motherboard
Action: Replace motherboard
Probable cause: Failure of interface module
Action: Replace interface module
Probable cause: Failure of GBIC module connector
Action: Replace GBIC module
Feb 12 08:48:29
0000DIAG-STATS, 1
00(regname) counter wrong on port nn, is nn sb nn
Probable cause: Failure of G_Port or FL_Port ASIC
Action: Replace interface module
Probable cause: Failure of Interface module
Vista de página 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 83 84

Comentários a estes Manuais

Sem comentários