Requires: Two HSG80 ACS kits, one host platform kit for each platform
type connected, host adapter (s), connectivity options, and disks to be
ordered separately.
Options: Optical hub (s), cables, UPS, cache upgrade, and fully redundant
power. See STEP 3 and STEP 4 for details.
ESA12000 High-bandwidth Base Model
380620-001 (60 Hz-Blue)
380620-002 (60 Hz-Opal)
380630-B21 (50 Hz-Blue)
380630-B22 (50 Hz-Opal)
Includes: Datacenter 41U cabinet/rack; two 24-slot enclosures with five
power supplies each (expandable to eight); four Fibre Channel HSG80 six-
channel controllers with 256 MB cache each (expandable to 512 MB each);
two 15-meter host-to-controller cables; power cord, and documentation.
Holds up to 48 drives, expandable to 72 drives per controller pair.
Requires: Four HSG80 ACS kits and one host platform kit for each
platform type connected, host adapter (s), connectivity options, and disks to
be ordered separately.
Options: Optical hub (s), cables, UPS, 256 MB cache upgrade and fully
redundant power. See STEP 3 and 4 for details.
ESA12000 Single-expansion Subsystem with Dual Controllers
380580-001 (60 Hz-Blue)
380580-002 (60 Hz-Opal)
380590-B21 (50 Hz-Blue)
380590-B22 (50 Hz-Opal)
Includes: Datacenter 41U cabinet/rack; One 24-slot enclosure with five
power supplies each (expandable to eight); dual Fibre Channel HSG80 six-
channel controllers with 256 MB cache each (expandable to 512 MB each);
15-meter host-to-controller cable; power cord and documentation. Up to 24
drives, expandable to 72 drives per controller pair using additional
cabinetry and enclosures.
Requires: Two HSG80 ACS kits and one host platform kit for each
platform type connected, host adapter(s), connectivity options, and disks to
be ordered separately.
Options: Optical hub (s), cables, UPS, 256 MB cache upgrade, and fully
redundant power. See STEP 3 and STEP 4 for details.
ESA12000 Dual-enclosure Expansion System
380640-001 (60 Hz-Blue)
380640-002 (60 Hz-Opal)
380650-B21 (50 Hz-Blue)
380650-B22 (50 Hz-Opal)
Includes: Datacenter 41U cabinet/rack; Two 24-slot enclosures with five
power supplies each (expandable to eight); two expansion cable kits; 41U
cabinet joiner kit; power cord and documentation. Holds up to 48 drives.
Requires: Disks to be ordered separately.
Options: Fully redundant power, UPS. See STEP 4 for details
STEP 2: Select the quantity of ACS kits needed and type of host platform-specific
solutions software and host bus adapters
A. Compaq HSG80 ACS Kits include: PC card (PCMCIA) containing the software for the storage array
controller and software license. One kit is required per array controller.
Order No. Description
380577-001 Array Controller Software for HSG80
B. Order one host-specific Platform Software Kit and adapter for the appropriate platform; kits include
SWCC management software.
Host Platform Platform Software
Kit (all V8.3)
Required Controller
Software
Supported Adapters
Windows NT
Intel/PCI
380551-001 ACS V8.3 380574-001
Sun Solaris/SBUS 380554-001 ACS V8.3 380575-001
SGI IRIX Origin
Series
380556-001 ACS V8.3 For Origin 2000 SGI
XT-FC-2P XIO and
X-F-OE-KIT (MIA)
For Origin 200 SGI