TECHNICAL USER MANUAL FOR: smartCore Express SMA200 Nordstrasse 11/F CH - 4542 Luterbach Tel.: ++41 (0)32 681 58 00 Fax: ++41 (0)32 681 58 0
DIGITAL-LOGIC AG SMA200 Manual V1.0 10 1.12. Swiss Quality 100% Made in Switzerland DIGITAL-LOGIC is a member of "Swiss-Label"
DIGITAL-LOGIC AG SMA200 Manual V1.0 11 2. OVERVIEW 2.1. Standard Features The smartCoreExpress is an electrical and mechanical definiti
DIGITAL-LOGIC AG SMA200 Manual V1.0 12 2.2. Technical Specifications CPU Specification CoreDuo / Celeron M Intel Atom 510 1.10GHz with 0.5MB
DIGITAL-LOGIC AG SMA200 Manual V1.0 13 Intel US15W Specification PCIe BUS 2x x1 Lane EIDE BUS 1x Ultra P-ATA 100 SATA BUS - USB V2.0 8 ch
DIGITAL-LOGIC AG SMA200 Manual V1.0 14 Operating Environment Specification Relative Humidity 5-90% non-condensing Vibration 5 to 2000 Hz Sho
DIGITAL-LOGIC AG SMA200 Manual V1.0 15 3. DIMENSIONS & DIAGRAMS 3.1. Block Diagram Temp. Sensor Intel Atom Processor CPU (power supply)
DIGITAL-LOGIC AG SMA200 Manual V1.0 16 Design IN with the smartModule Attention! When using an active/passive heatsink that is not from DLAG, b
DIGITAL-LOGIC AG SMA200 Manual V1.0 17 3.3. Connector Placement & Pin Definition on the Carrier Board View of the Top Side (mounting side)
DIGITAL-LOGIC AG SMA200 Manual V1.0 18 3.4. Photo of the Top Side of the PCB Pin 1 65mm 58mm
DIGITAL-LOGIC AG SMA200 Manual V1.0 19 3.5. Dimensions of the Carrier Board Connector SMX-CON8: Standard Height: 5.0mm (Available alternative
DIGITAL-LOGIC AG SMA200 Manual V1.0 2 For internal use only: File: SMA200_TechManual_V1.0.doc Path: R:\HANDBUCH\smart\SMA200\SMA200_TechMa
DIGITAL-LOGIC AG SMA200 Manual V1.0 20 4. COM-EXPRESS CONNECTOR DESCRIPTION 4.1. Signal Terminology Descriptions Signal Description PU Inte
DIGITAL-LOGIC AG SMA200 Manual V1.0 21 4.2. smartCoreExpress Connector Pinout BUS on the smartCoreExpress – Connectors A / B: Pins 1-55 Pin S
DIGITAL-LOGIC AG SMA200 Manual V1.0 22 BUS on the smartCoreExpress – Connectors A / B: Pins 56-110 Pin Signal BUS Type Remarks Pin Signal
DIGITAL-LOGIC AG SMA200 Manual V1.0 23 5. SIGNAL DESCRIPTIONS OF THE SMARTCOREEXPRESS 5.1. Wire Design for Typical Impedances 5.2. Match
DIGITAL-LOGIC AG SMA200 Manual V1.0 24 5.3. Placing an AC Coupling Capacitor on each PCIe-TX In the smartCoreExpress module, all PCI-TX pairs a
DIGITAL-LOGIC AG SMA200 Manual V1.0 25 5.4. smartCoreExpress Signal Groups 5.4.1. PCI-Express Signal BUS Type Description On Module Termin
DIGITAL-LOGIC AG SMA200 Manual V1.0 26 5.4.2. SDVO Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Length in
DIGITAL-LOGIC AG SMA200 Manual V1.0 27 5.4.3. LVDS Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Length i
DIGITAL-LOGIC AG SMA200 Manual V1.0 28 5.4.4. USB Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Length in
DIGITAL-LOGIC AG SMA200 Manual V1.0 29 5.4.5. Parallel ATA Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. L
DIGITAL-LOGIC AG SMA200 Manual V1.0 3 Table of Contents 1. PREFACE ...
DIGITAL-LOGIC AG SMA200 Manual V1.0 30 5.4.6. LPC BUS Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Lengt
DIGITAL-LOGIC AG SMA200 Manual V1.0 31 5.4.7. SMBus Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Length
DIGITAL-LOGIC AG SMA200 Manual V1.0 32 5.4.8. HDA Audio Interface Signal BUS Type Description On Module Termination Ext. Ter-mination Neede
DIGITAL-LOGIC AG SMA200 Manual V1.0 33 5.4.9. SD / SDIO Interface Signal BUS Type Description On Module Termination Ext. Ter-mination Neede
DIGITAL-LOGIC AG SMA200 Manual V1.0 34 5.4.10. SPI BUS Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Leng
DIGITAL-LOGIC AG SMA200 Manual V1.0 35 5.4.11. SATA Interface (Option) Signal BUS Type Description On Module Termination Ext. Ter-mination
DIGITAL-LOGIC AG SMA200 Manual V1.0 36 5.4.12. GLAN Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Length i
DIGITAL-LOGIC AG SMA200 Manual V1.0 37 5.4.13. CAN / Serial Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max.
DIGITAL-LOGIC AG SMA200 Manual V1.0 38 5.4.14. PM Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Length in
DIGITAL-LOGIC AG SMA200 Manual V1.0 39 5.4.15. Supply Signal BUS Type Description On Module Termination Ext. Ter-mination Needed Max. Lengt
DIGITAL-LOGIC AG SMA200 Manual V1.0 4 1. PREFACE The information contained in this manual has been carefully checked and is believed
DIGITAL-LOGIC AG SMA200 Manual V1.0 40 6. SMARTCORE-EXPRESS CONNECTOR SPECIFICATIONS The connector type is equal to the COMexpress conn
DIGITAL-LOGIC AG SMA200 Manual V1.0 41 7. SMARTCORE-EXPRESS VERSUS COMEXPRESS The smartCoreExpress supports small footprints and especial
DIGITAL-LOGIC AG SMA200 Manual V1.0 42 8. INDEX A AC Coupling Capacitor... 24 B Block Diagram...
DIGITAL-LOGIC AG SMA200 Manual V1.0 5 1.5. Recycling Information All components within this product fulfill the requirements of the RoHS (Rest
DIGITAL-LOGIC AG SMA200 Manual V1.0 6 1.8. Explanation of Symbols CE Conformity This symbol indicates that the product described in thi
DIGITAL-LOGIC AG SMA200 Manual V1.0 7 1.9. Applicable Documents and Standards The following publications are used in conjunction with t
DIGITAL-LOGIC AG SMA200 Manual V1.0 8 Smart Battery Data Specification Revision 1.1, December 11, 1998. www.sbs-forum.org System Manageme
DIGITAL-LOGIC AG SMA200 Manual V1.0 9 RoHS is often referred to as the "lead-free" directive but it restricts the use of the following