Resumo do Conteúdo

Página 1 - ProLiant ML370

ProLiant ML370Maintenance and Service GuideFourth Edition (June 2000)Part Number 143091-004Spare Part Number 158549-001Compaq Computer Corporation

Página 2 - Spare Part Number 158549-001

Chapter 1Illustrated Parts CatalogThis chapter provides the illustrated parts breakdown and a spare parts list forCompaq ProLiant™ ML370 Servers. See

Página 3 - Contents

3-46 Compaq ProLiant ML370 Maintenance and Service GuideIntegrated Management LogOn servers supporting the Integrated Management Display, the Compaq

Página 4 - Chapter 3

Diagnostics and Troubleshooting 3-47Viewing the Event List 1. From Compaq Insight Manager, select the appropriate server, then select View DeviceDat

Página 5

3-48 Compaq ProLiant ML370 Maintenance and Service GuideEvent ListThe Event List displays the affected components and the associated error messages.

Página 6

Diagnostics and Troubleshooting 3-49Table 3-17Event Messages continuedEvent Type Event Message ActionProcessorCorrectable ErrorThreshold exceededPro

Página 7 - About This Guide

3-50 Compaq ProLiant ML370 Maintenance and Service GuideRapid Error RecoveryCompaq servers provide rapid recovery services for diagnosing and recove

Página 8 - Compaq Technician Notes

Diagnostics and Troubleshooting 3-51The available recovery features are: Software Error Recoveryautomatically restarts the server after a softwar

Página 9 - Telephone Numbers

3-52 Compaq ProLiant ML370 Maintenance and Service GuideHardware RequirementsTo use this level of ASR-2 over a modem, you need the following: A Co

Página 10 - Illustrated Parts Catalog

Diagnostics and Troubleshooting 3-53You can configure the server to start Compaq Utilities in four different ways: Without remote console support;

Página 11

3-54 Compaq ProLiant ML370 Maintenance and Service GuideCompaq Integrated Remote ConsoleThe standard Compaq Integrated Remote Console performs a wid

Página 12 - Mechanical Spare Parts List

Diagnostics and Troubleshooting 3-55The following ASR-2 flow chart shows you the sequence of events after a hardware or softwareerror occurs:Hardwar

Página 13

1-2 Compaq ProLiant ML370 Maintenance and Service GuideMechanical Parts Exploded View23457861Figure 1-1. Mechanical parts exploded view

Página 14 - System Components Spare Parts

3-56 Compaq ProLiant ML370 Maintenance and Service GuideBooting into Compaq UtilitiesWhen you enable ASR-2 to start into Compaq Utilities and a crit

Página 15 - Table 1-2

Diagnostics and Troubleshooting 3-57Table 3-19Compaq System Configuration Utility Pager Settings for Booting into Compaq Utilities continuedPager Da

Página 16

3-58 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-19Compaq System Configuration Utility Pager Settings for Booting into Compaq Utiliti

Página 17 - Chapter 2

Diagnostics and Troubleshooting 3-59The System Configuration Utility setting should resemble the following when you enable ASRto restart into the op

Página 18 - Symbols in Equipment

3-60 Compaq ProLiant ML370 Maintenance and Service GuideASR-2 Integrated Management Log MessagesThe Integrated Management Log (IML) records memory e

Página 19 - Preparation Procedures

Diagnostics and Troubleshooting 3-61Table 3-21ASR-2 IML Messages continuedMessage DescriptionNMI—PCI Bus Parity Error A parity error was detected on

Página 20 - Rack Warnings

3-62 Compaq ProLiant ML370 Maintenance and Service GuideRevision History TableSome errors can be resolved by reviewing changes to the server configu

Página 21

Diagnostics and Troubleshooting 3-63Storage Fault Recovery TrackingThis feature tracks over 12 failure-indication parameters, such as timeouts, spin

Página 22 - Front Bezel

3-64 Compaq ProLiant ML370 Maintenance and Service GuideRemote Service FeaturesCompaq servers have the following management features that you can ac

Página 23 - Rack Front Plate

Diagnostics and Troubleshooting 3-65ROMPaq Disaster RecoveryThe following option should be utilized by any server that does not have a valid ROM ima

Página 24

Illustrated Parts Catalog 1-3Mechanical Spare Parts ListTable 1-1Mechanical Spare Parts ListItem Description Spare Part NumberChassis1 Chassis 15798

Página 25 - Large Access Panel

3-66 Compaq ProLiant ML370 Maintenance and Service Guide 10. After successful completion of this process, a. Power down the server b. Remove the dis

Página 26 - Small Access Panel

Diagnostics and Troubleshooting 3-67Compaq Insight ManagerCompaq Insight Manager is the Compaq application for easily managing network devices.Compa

Página 27 - Right Side Panel

3-68 Compaq ProLiant ML370 Maintenance and Service Guide SNMP standards provide integration with other management products. Flexible network co

Página 28 - Drives and Related Components

Chapter 4Connectors, Switches, and LED IndicatorsThis chapter provides connector, switch, and LED indicator information for CompaqProLiant ML370 Serve

Página 29 - Cable Routing Diagrams

4-2 Compaq ProLiant ML370 Maintenance and Service GuideCompaq ProLiant ML370 System Board ComponentsSee Table 4-1 for the names of the Compaq ProLia

Página 30 - SCSI Cable Diagram

Connectors, Switches, and LED Indicators 4-3Rear Panel ComponentsSee Table 4-2 for the names of the Compaq ProLiant ML370 rear panel components.1234

Página 31 - Hot-Plug Drive Cage

4-4 Compaq ProLiant ML370 Maintenance and Service GuideSwitchesThe Compaq ProLiant ML370 Server has two switchbanks (SW1 and SW2) located on thesyst

Página 32

Connectors, Switches, and LED Indicators 4-5SW1 – System Identification Switch SettingsThe processor configuration switchbank (SW1) is an eight-posi

Página 33 - Diskette Drive

4-6 Compaq ProLiant ML370 Maintenance and Service GuideLED IndicatorsThis section contains graphics and tables showing LED indicator locations and f

Página 34 - Hard Drive Blank

Connectors, Switches, and LED Indicators 4-7RJ-45 ConnectorFigure 4-5 and Table 4-6 show the location and a description of the RJ-45 connector LEDin

Página 35 - Hot-Plug SCSI Hard Drive

1-4 Compaq ProLiant ML370 Maintenance and Service GuideSystem Components Exploded View152021a191913168221012261127a181714aFigure 1-2. System compon

Página 36

4-8 Compaq ProLiant ML370 Maintenance and Service GuideSystem BoardFigure 4-6 and Table 4-7 show the location and meaning of the indicators.1234 5 6

Página 37

Connectors, Switches, and LED Indicators 4-9Riser BoardFigure 4-7 and Table 4-8 show the location and meaning of the riser board indicator.11Figure

Página 38

Chapter 5Physical and Operating SpecificationsThis chapter provides operating and performance specifications for the CompaqProLiant ML370 Server compo

Página 39

5-2 Compaq ProLiant ML370 Maintenance and Service GuideSystem UnitTable 5-1System Unit SpecificationsDimensionsHeight (without feet) 45.52 cm (17.9

Página 40

Physical and Operating Specifications 5-3Power SupplyTable 5-2Power Supply SpecificationsInput specificationsRated input voltage 100 – 240 VACRated

Página 41 - Riser Board Expansion Slots

5-4 Compaq ProLiant ML370 Maintenance and Service GuideRedundant Power SupplyTable 5-3Redundant Power Supply SpecificationsInput specificationsRated

Página 42 - I/O Expansion Slot Cover

Physical and Operating Specifications 5-5Dual Inline Memory Modules (DIMM)Table 5-4DIMM SpecificationsSize 64-, 128-, 256-, 512 MB, or 1 GBSpeed 133

Página 43 - I/O Expansion Board

5-6 Compaq ProLiant ML370 Maintenance and Service GuideIDE CD-ROM DriveTable 5-6IDE CD-ROM Drive SpecificationsApplicable disk CD-ROM (modes 1 and 2

Página 44 - Riser Board and Brace

Physical and Operating Specifications 5-7Compaq Wide Ultra2 Hot-Plug SCSI Hard DrivesTable 5-7Compaq Wide Ultra2 Hot-Plug SCSI Hard Drive Specificat

Página 45 - Processor

5-8 Compaq ProLiant ML370 Maintenance and Service GuideIntegrated Dual Channel SCSI ControllerTable 5-8Integrated Dual Channel SCSI Controller Speci

Página 46 - Processor Power Module

Illustrated Parts Catalog 1-5System Components Spare PartsTable 1-2System Components Spare Parts ListItem Description Spare Part NumberSystem Compon

Página 47 - SDRAM DIMM Slot Locations

IndexAaccess panelslarge accesspart number 1-3removing 2-9removing, illustrated 2-9replacing 2-9right sidepart number 1-3removing 2-11remo

Página 48

2 Compaq ProLiant ML370 Maintenance and Service Guidesoftware errorrecovery 3-53recovery boot option 3-53recovery time-out 3-53standby recover

Página 49

Index 3remote maintenance 3-68viewing the event list 3-47Compaq Integrated Remote Consolefeatures 3-54Compaq Integrated Smart ArrayControllerl

Página 50

4 Compaq ProLiant ML370 Maintenance and Service Guidetransporting parts safely 2-2workstationrecommendations 2-2environmental recovery 3-51err

Página 51 - Hot-Plug SCSI Drive Backplane

Index 5correctable errorthreshold exceeded 3-48,3-49Diagnostic Error 3-60dirty data 3-36disable command issued 3-39drive (bay)drive X failed

Página 52

6 Compaq ProLiant ML370 Maintenance and Service Guidepower AC overload 3-49power modulefailure 3-49not redundant 3-49power supplyfailure 3-4

Página 53

Index 7Compaq Integrated Smart ArrayController upgrade module,removing 2-37CPU fan, removing 2-21DIMM slots on systemboard 2-31diskette drive,

Página 54 - Internal Replacement Battery

8 Compaq ProLiant ML370 Maintenance and Service Guidetest error codes 3-29kitsdata cable, part number 1-5hardware, part number 1-6plastics, pa

Página 55

Index 9right sidepart number 1-3removing 2-11removing, illustrated 2-11replacing 2-11small accesspart number 1-3removing 2-10removing, i

Página 56 - Diagnostic Tools

10 Compaq ProLiant ML370 Maintenance and Service GuideRrack conversion kit, part number 1-6rack front plate See front platerack warnings 2-4Ra

Página 57

1-6 Compaq ProLiant ML370 Maintenance and Service GuideTable 1-2System Components Spare Parts List continuedItem Description Spare Part NumberCables

Página 58 - Default Configuration

Index 11standby recoveryserver option 3-53server port 3-53time-out 3-53static electricity See electrostaticdischargestorage automatic recons

Página 59 - Utilities Access

12 Compaq ProLiant ML370 Maintenance and Service GuideRiser Board ExpansionSlots 2-25Riser Board LED Indicator 4-9RJ-45 Connected LEDIndicators

Página 60 - Software CD

Index 13Firmware Upgrade,accessing 3-5Health Driver 3-54IML Management utility,defined 3-47Inspectaccessing 3-2, 3-26description 3-2, 3-4p

Página 61 - Power-On Self-Test (POST)

Illustrated Parts Catalog 1-7Table 1-2System Components Spare Parts List continuedItem Description Spare Part NumberOptions continued42 9.1-GB, 1-in

Página 62 - POST Error Messages

Chapter 2Removal and Replacement ProceduresThis chapter provides subassembly/module-level removal and replacement procedures forCompaq ProLiant ML370

Página 63

2-2 Compaq ProLiant ML370 Maintenance and Service GuideElectrostatic Discharge InformationA discharge of static electricity can damage static-sensit

Página 64

Removal and Replacement Procedures 2-3Weight in kgWeight in lbAny product or assembly marked with these symbols indicates that thecomponent exceeds

Página 65

NoticeThe information in this publication is subject to change without notice.COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OREDITORIA

Página 66

2-4 Compaq ProLiant ML370 Maintenance and Service GuideWARNING: To reduce the risk of personal injury or damage to the equipment: If the server ism

Página 67

Removal and Replacement Procedures 2-5Server Warnings and PrecautionsWARNING: To reduce the risk of personal injury from hot surfaces, allow the in

Página 68

2-6 Compaq ProLiant ML370 Maintenance and Service GuideFront BezelNOTE: This procedure applies to the ProLiant ML370 tower model only.To open the f

Página 69

Removal and Replacement Procedures 2-7Rack Front PlateNOTE: This procedure applies to the ProLiant ML370 rack-mountable model only.To remove the ra

Página 70

2-8 Compaq ProLiant ML370 Maintenance and Service GuideFeetNOTE: This procedure applies to the ProLiant ML370 tower model only.To remove the feet f

Página 71

Removal and Replacement Procedures 2-9Large Access PanelWARNING: To reduce the risk of personal injury from hot surfaces, allow internal systemcomp

Página 72

2-10 Compaq ProLiant ML370 Maintenance and Service GuideSmall Access PanelWARNING: To reduce the risk of personal injury from hot surfaces, allow i

Página 73

Removal and Replacement Procedures 2-11Right Side PanelNOTE: This panel does not exist on the rack-mountable model. This procedure applies to the t

Página 74

2-12 Compaq ProLiant ML370 Maintenance and Service GuideDrives and Related ComponentsCompaq ProLiant ML370 Servers ship standard with a hot-plug dri

Página 75

Removal and Replacement Procedures 2-13Cable Routing DiagramsCAUTION: When routing cables, always ensure that the cables are not in a position wher

Página 76

ContentsAbout This GuideSymbols in Text...viiCom

Página 77

2-14 Compaq ProLiant ML370 Maintenance and Service GuideSCSI Cable Diagram1122Figure 2-10. SCSI cable diagram: the three-device, terminated SCSI

Página 78

Removal and Replacement Procedures 2-15Hot-Plug Drive CageTo remove the hot-plug drive cage: 1. Perform the preparation procedures. See “Powering D

Página 79

2-16 Compaq ProLiant ML370 Maintenance and Service GuideIDE CD-ROM DriveTo remove the CD-ROM drive: 1. Perform the preparation procedures. See “Pow

Página 80 - Diagnostics Software

Removal and Replacement Procedures 2-17Diskette DriveTo remove the diskette drive: 1. Perform the preparation procedures. See “Powering Down the Se

Página 81 - Table 3-3

2-18 Compaq ProLiant ML370 Maintenance and Service GuideHard Drive BlankIMPORTANT: A hard drive blank must be installed in an unused hard drive slo

Página 82 - Memory Test Error Codes

Removal and Replacement Procedures 2-19Hot-Plug SCSI Hard DriveTo remove a hot-plug SCSI hard drive: 1. Open the front bezel (tower model only). Se

Página 83 - Table 3-6

2-20 Compaq ProLiant ML370 Maintenance and Service GuideRemovable Media Drive Bay BlankTo remove a removable media drive bay blank: 1. Open the fro

Página 84 - Table 3-7

Removal and Replacement Procedures 2-21CPU FanTo remove the CPU fan: 1. Perform the preparation procedures. See “Powering Down the Server” earlier

Página 85 - Serial Test Error Codes

2-22 Compaq ProLiant ML370 Maintenance and Service GuideI/O FanTo remove the I/O fan: 1. Perform the preparation procedures. See “Powering Down the

Página 86 - Table 3-11

Removal and Replacement Procedures 2-23Power Switch with Cable and LED IndicatorsTo remove the power switch and cable assembly: 1. Perform the prep

Página 87 - Table 3-13

iv Compaq ProLiant ML370 Maintenance and Service GuideRemoval and Replacement ProcedurescontinuedI/O Fan...

Página 88 - Table 3-15

2-24 Compaq ProLiant ML370 Maintenance and Service Guide 6. Disconnect the power switch from the system board . 4Figure 2-20. Unplugging the powe

Página 89 - Starting ADU

Removal and Replacement Procedures 2-25Riser Board Expansion Slots23456123456Figure 2-21. Riser board expansion slotsTable 2-2Riser Board Expansion

Página 90 - ADU Diagnostic Messages

2-26 Compaq ProLiant ML370 Maintenance and Service GuideI/O Expansion Slot CoverTo remove an I/O expansion slot cover: 1. Perform the preparation p

Página 91

Removal and Replacement Procedures 2-27I/O Expansion BoardTo remove an I/O expansion board: 1. Perform the preparation procedures. See “Powering Do

Página 92

2-28 Compaq ProLiant ML370 Maintenance and Service GuideRiser Board and BraceTo remove the riser board and brace: 1. Perform the preparation proced

Página 93

Removal and Replacement Procedures 2-29ProcessorTo remove the processor: 1. Perform the preparation procedures. See “Powering Down the Server” earl

Página 94

2-30 Compaq ProLiant ML370 Maintenance and Service GuideProcessor Power ModuleTo remove the Processor Power Module: 1. Perform the preparation proc

Página 95

Removal and Replacement Procedures 2-31MemoryCompaq ProLiant ML370 Servers ship standard with a 128-MB Synchronous DRAM(SDRAM) dual inline memory mo

Página 96

2-32 Compaq ProLiant ML370 Maintenance and Service GuideTo remove an SDRAM DIMM: 1. Perform the preparation procedures. See “Powering Down the Serv

Página 97

Removal and Replacement Procedures 2-33Power SupplyWARNING: To reduce the risk of electric shock, do not disassemble the power supply orattempt to

Página 98

Contents vDiagnostics and TroubleshootingcontinuedRemote Service Features ...

Página 99

2-34 Compaq ProLiant ML370 Maintenance and Service Guide 6. Disconnect all other power supply cables. 7. Remove the four Torx T-15 screws securing

Página 100 - Integrated Management Log

Removal and Replacement Procedures 2-35Hot-Plug SCSI Drive BackplaneTo remove the hot-plug SCSI drive backplane: 1. Perform the preparation procedu

Página 101 - Compaq IML Management Utility

2-36 Compaq ProLiant ML370 Maintenance and Service GuideSystem BoardTo remove the system board: 1. Perform the preparation procedures. See “Powerin

Página 102 - Event Messages

Removal and Replacement Procedures 2-37Compaq Integrated Smart Array Controller UpgradeModuleNOTE: The Compaq Integrated Smart Array Controller upg

Página 103 - Table 3-17

2-38 Compaq ProLiant ML370 Maintenance and Service GuideInternal Replacement BatteryWARNING: This server contains an internal lithium manganese dio

Página 104 - Rapid Error Recovery

Chapter 3Diagnostics and TroubleshootingThis chapter describes software and firmware diagnostic tools available for all Compaq serverproducts. The sec

Página 105 - Attended Recovery

3-2 Compaq ProLiant ML370 Maintenance and Service GuideDiagnostic Tools Utility OverviewThese utilities were developed to assist in diagnosing probl

Página 106 - Hardware Requirements

Diagnostics and Troubleshooting 3-3Table 3-1Diagnostic Tools continuedTool What it is How to run itArray DiagnosticsUtility (ADU)A Windows-based too

Página 107 - ASR-2 Features

3-4 Compaq ProLiant ML370 Maintenance and Service GuideDefault ConfigurationWhen the system is first powered up, the system ROM detects the unconfig

Página 108 - Compaq Health Driver

Diagnostics and Troubleshooting 3-5Utilities AccessThe Compaq SmartStart and Support Software CD contains the SmartStart program and manyof the Comp

Página 110 - Table 3-19

3-6 Compaq ProLiant ML370 Maintenance and Service GuideRunning the Utilities from Diskette Run the utilities from their individual diskettes. If y

Página 111

Diagnostics and Troubleshooting 3-7Power-On Self-Test (POST)POST is a series of diagnostic tests that run automatically on Compaq computers when the

Página 112

3-8 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error MessagesError Code Audible Beeps Probable Source of Problem Recommended A

Página 113 - ASR-2 Security

Diagnostics and Troubleshooting 3-9Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action175 -

Página 114 - ASR-2 IML Messages

3-10 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Re

Página 115

Diagnostics and Troubleshooting 3-11Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended ActionZZ-3

Página 116 - Table 3-22

3-12 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Re

Página 117

Diagnostics and Troubleshooting 3-13Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1702

Página 118 - ROMPaq Error Recovery Options

3-14 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Re

Página 119 - ROMPaq Disaster Recovery

Diagnostics and Troubleshooting 3-15Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1731

Página 120 - b. Remove the diskette

About This GuideThis maintenance and service guide is a troubleshooting guide that can be used for referencewhen servicing Compaq ProLiant ML370 Serve

Página 121 - Compaq Insight Manager

3-16 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Re

Página 122 - Insight Management Agents

Diagnostics and Troubleshooting 3-17Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1774

Página 123 - Chapter 4

3-18 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Re

Página 124 - System Board Components

Diagnostics and Troubleshooting 3-19Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1778

Página 125 - Rear Panel Components

3-20 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Re

Página 126 - Switches

Diagnostics and Troubleshooting 3-21Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1786

Página 127 - Table 4-4

3-22 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Re

Página 128 - LED Indicators

Diagnostics and Troubleshooting 3-23Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1789

Página 129 - RJ-45 Connector

3-24 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Re

Página 130 - System Board

Diagnostics and Troubleshooting 3-25Table 3-2POST Error Messages continuedError Code Audible Beeps Probable Source of Problem Recommended Action1797

Página 131 - Riser Board

viii Compaq ProLiant ML370 Maintenance and Service GuideCompaq Technician NotesWARNING: Only authorized technicians trained by Compaq should attemp

Página 132 - Chapter 5

3-26 Compaq ProLiant ML370 Maintenance and Service GuideDiagnostics SoftwareTest Error Codes Tables include all test error codes generated by Compaq

Página 133 - System Unit

Diagnostics and Troubleshooting 3-27100-199, Primary Processor Test Error CodesThe 100 series of diagnostic error codes identifies failures with pro

Página 134 - Power Supply

3-28 Compaq ProLiant ML370 Maintenance and Service Guide200-299, Memory Test Error CodesThe 200 series of diagnostic error codes identifies failures

Página 135 - Redundant Power Supply

Diagnostics and Troubleshooting 3-29300-399, Keyboard Test Error CodesThe 300 series of diagnostic error codes identifies failures with keyboard and

Página 136 - 1.44-MB Diskette Drive

3-30 Compaq ProLiant ML370 Maintenance and Service Guide500-599, Graphics Controller Unit Test Error CodesThe 500 series of diagnostic error codes i

Página 137 - IDE CD-ROM Drive

Diagnostics and Troubleshooting 3-31600-699, Diskette Drive Test Error CodesThe 600 series of diagnostic error codes identifies failures with disket

Página 138 - Table 5-7

3-32 Compaq ProLiant ML370 Maintenance and Service Guide1200-1299, Modem Communications Test Error CodesThe 1200 series of diagnostic error codes id

Página 139 - Table 5-8

Diagnostics and Troubleshooting 3-336500-6599, SCSI Hard Drive Test Error CodesThe 6500 series of diagnostic error codes identifies failures with SC

Página 140

3-34 Compaq ProLiant ML370 Maintenance and Service Guide6700-6799, SCSI Tape Drive Test Error CodesThe 6700 series of diagnostic error codes identif

Página 141

Diagnostics and Troubleshooting 3-35Array Diagnostic Utility (ADU)Array Diagnostic Utility (ADU) is a Windows-based software tool designed to run on

Página 142

About This Guide ixIntegrated Management DisplaySome Compaq server models include a Compaq Integrated Management Display (IMD), anintegrated, 16 × 4

Página 143

3-36 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-16ADU Diagnostic MessagesMessage Description Recommended ActionAcceleratorboard notd

Página 144

Diagnostics and Troubleshooting 3-37Table 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionAcceleratorstatus: ExcessiveECC

Página 145

3-38 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionAdapter/NVR

Página 146

Diagnostics and Troubleshooting 3-39Table 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionController is notconfiguredIf c

Página 147

3-40 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionDrive (bay)

Página 148

Diagnostics and Troubleshooting 3-41Table 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionError occurredreading RIS copyf

Página 149

3-42 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionLogical Dri

Página 150

Diagnostics and Troubleshooting 3-43Table 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionLoose cabledetected—logical dri

Página 151

3-44 Compaq ProLiant ML370 Maintenance and Service GuideTable 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionSCSI Port x

Página 152

Diagnostics and Troubleshooting 3-45Table 3-16ADU Diagnostic Messages continuedMessage Description Recommended ActionWarning bitdetectedA monitor an