Compaq StorageWorks 1000 - Modular Smart Array Manual de Serviço Página 67

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 122
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 66
Determining wh
ether a component is hot-pluggable
Before removin
g any serviceable part, determine whether the part is hot-pluggable or non-hot-pluggable.
If the component is hot-pluggable, a power shutdown of the device is not required for replacement
of the part.
If the component is not hot-pluggable, the device must be powered down.
CAUTION:
Be sure the rep
lacement is available before removing a component or blanking panel from the chassis.
Open slots dr
amatically impact airow and cooling within the enclosure.
Table 3 Component hot-pluggability
Component
Hot-pluggable Non hot-pluggable
Redundant power supply/fan assembly
X
MSA array controller
(dual-controller congurations)
X*
Fibre Channel I/O module
(dual-controller congurations)
X*
SCSI I/O module
X
MSA chassis
X
Power switch module
X
MSA array controller
(single-controller congurations)
X
Fibre Channel I/O module
(single-controller congurations)
X
* Before removing one of the two controllers or Fibre Channel I/O modules in an operational dual-controller
MSA, the controller being removed must rst be disabled. For more information, see Replacing the controller,
controller cache, or controller battery .